fix(battery): harden charge-complete inference
This commit is contained in:
@@ -979,6 +979,28 @@ menu "Example Configuration"
|
||||
range 0 1
|
||||
depends on TQ_BATTERY_ENABLE
|
||||
|
||||
config TQ_BATTERY_FULL_MIN_VOLTAGE_MV
|
||||
int "Minimum voltage for charge-complete prompt (mV)"
|
||||
default 4150
|
||||
range 4000 4200
|
||||
depends on TQ_BATTERY_ENABLE
|
||||
help
|
||||
The TP4057 status pin cannot distinguish charge termination
|
||||
from charger removal. Require at least this filtered battery
|
||||
voltage before inferring that charging has completed.
|
||||
|
||||
config TQ_BATTERY_FULL_MIN_PERCENT
|
||||
int "Minimum level for charge-complete prompt (percent)"
|
||||
default 95
|
||||
range 90 100
|
||||
depends on TQ_BATTERY_ENABLE
|
||||
|
||||
config TQ_BATTERY_FULL_CONFIRM_SEC
|
||||
int "Charge-complete stable confirmation time (seconds)"
|
||||
default 30
|
||||
range 5 300
|
||||
depends on TQ_BATTERY_ENABLE
|
||||
|
||||
config TQ_BATTERY_DIVIDER_HIGH_OHM
|
||||
int "Battery divider resistance from VBAT to ADC (ohm)"
|
||||
default 100000
|
||||
|
||||
Reference in New Issue