3.4 KiB
Device Bootstrap Flow
Purpose
Device bootstrap maps a factory IMEI to Banban's internal device_id and
serial_number, and returns the associated ICCID for downstream SIM/traffic
binding. Devices do not need to know those IDs before first bootstrap.
Flow
sequenceDiagram
autonumber
participant Factory as Factory Excel / import CSV
participant Mapping as device_imei_mapping
participant Device as TalkingQ device
participant MQTT as MQTT broker
participant Handler as TalkingQMQTTService
participant Init as device_identity_initializer
participant Auth as device_auth
Factory->>Mapping: Insert imei, device_id, serial_number, status=pending
Device->>MQTT: Publish device/{imei}/event msg_id=012
MQTT->>Handler: Deliver identity init event
Handler->>Init: initialize_by_imei(imei)
Init->>Mapping: SELECT mapping by imei
alt mapping missing or incomplete
Init-->>Handler: DeviceIdentityInitializationError
Handler-->>MQTT: device/{imei}/event_resp status=failed
else mapping found
Init->>Auth: SELECT device_auth by device_id
alt no auth row
Init->>Auth: INSERT device_id, serial_number, is_active=1
else auth row exists and serial matches
Init->>Auth: UPDATE is_active=1
else serial mismatch
Init-->>Handler: device_auth serial_number conflict
Handler-->>MQTT: device/{imei}/event_resp status=failed
end
Init->>Mapping: UPDATE status=activated, activated_at=now
Handler-->>MQTT: device/{imei}/event_resp with device_id, device_sn, and iccid
MQTT-->>Device: Receive assigned identity
end
Successful Response
When the IMEI mapping and its authoritative ICCID association are available,
the handler returns the assigned identity and ICCID in the msg_id=012
response:
{
"msg_id": "012",
"params": {
"device_id": "TalkingQ_ZHWK00002110",
"device_sn": "TQ_ZHWK000000002110",
"iccid": "898604E91123D1334901"
}
}
The iccid value is the canonical, full ICCID used by the downstream SIM and
traffic service. It must come from an authoritative IMEI-to-ICCID provisioning
record or a validated device report; it must not be derived from the IMEI.
Successful bootstrap requires a non-empty, valid ICCID. If the ICCID cannot
be resolved or fails consistency validation, the handler must return the
existing msg_id=012 failure response instead of returning a partial success.
Adding params.iccid is an additive response-field change. Devices that ignore
unknown JSON fields remain compatible, while strict firmware parsers need a
protocol/version capability check before this response is enabled for them.
Data Model
erDiagram
device_imei_mapping {
int id PK
varchar imei UK
varchar device_id UK
varchar serial_number
varchar status
datetime activated_at
datetime created_at
datetime updated_at
}
device_auth {
int id PK
varchar device_id UK
varchar serial_number
varchar batch_id
tinyint is_active
datetime created_at
datetime updated_at
}
device_imei_mapping ||--o| device_auth : activates
Current ID Style
device_id: TalkingQ_ZHWK00002001
serial_number: TQ_ZHWK000000002001
Source Anchors
- Bootstrap handler:
talkingq-url/handlers/mqtt_handler.py - Identity initializer:
talkingq-url/services/device_identity_initializer.py - Import script:
talkingq-url/scripts/import_device_imei_mapping.py - Tables:
database/talkingq_shared_schema.sql